The magic of moulding – Applying upper limb cast in a child
Journal of Clinical Orthopaedics | Vol 7 | Issue 2 | Jul-Dec 2022 | page: 15-17 | Chintan Doshi
DOI: 10.13107/jcorth.2022.v07i02.515
Author: Chintan Doshi [1]
[1] Consultant Orthopedic Surgeon, Department of Orthopedics, Seth V.C. Gandhi & M. A Vora Municipal General
Rajawadi Hospital, Mumbai, India.
Address of Correspondence
Dr. Chintan Doshi,
1304, Building No 92, B wing, Road No 13, Tilaknagar, Chembur West, Mumbai 400089, India.
E-mail: drchintandoshi@gmail.com
Abstract
Upper limb fractures are common in pediatric population. Most of these injuries need application of cast as a routine procedure. The purpose of this review is to discuss the art of applying a well moulded upper limb cast in children in order to get excellent outcome. Material to be selected for cast application depends on the fracture configuration, requirement for moulding, and other physical properties of the cast required for particular patient. A well –moulded cast should be applied in order to prevent further fracture displacement. It is important to understand and maintain certain radiographic indices in order to ensure a good outcome from casting technique. Preventing cast related complications like wet cast, skin complication, compartment syndrome, thermal injuries, and cast syndrome are important consideration when taking care of the cast. Patient education is one of the most important factor in ensuring proper cast maintenance.
Keywords: Pediatric fractures, Upperlimb cast, Casting, Cast technique, Cast complication
References
1. Halanski M, Noonan KJ. Cast and splint immobilization: complications. J Am Acad Orthop Surg. 2008;16:30–40.
2. Iltar S, Alemdaroğlu KB, Say F, Aydoğan NH. The value of the three-point index in predicting redisplacement of diaphyseal fractures of the forearm in children. Bone Joint J. 2013;95-B:563–567. .
3. Wolff CR, James P. The prevention of skin excoriation under children’s hip spica casts using the goretex pantaloon. J Pediatr Orthop. 1995;15:386–388.
4. Webb GR, Galpin RD, Armstrong DG. Comparison of short and long arm plaster casts for displaced fractures in the distal third of the forearm in children. J Bone Joint Surg Am. 2006;88:9–17.
5. Chess DG, Hyndman JC, Leahey JL, Brown DC, Sinclair AM. Short arm plaster cast for distal pediatric forearm fractures. J Pediatr Orthop. 1994;14:211–213.
6. Bhatia M, Housden PH. Redisplacement of paediatric forearm fractures: Role of plaster moulding and padding. Injury. 2006 Mar 1;37(3):259-68.
7. Malviya A, Tsintzas D, Mahawar K, Bache CE, Glithero PR. Gap index: a good predictor of failure of plaster cast in distal third radius fractures. Journal of Pediatric Orthopaedics B. 2007 Jan 1;16(1):48-52.
8. Edmonds EW, Capelo RM, Stearns P, Bastrom TP, Wallace CD, Newton PO. Predicting initial treatment failure of
fiberglass casts in pediatric distal radius fractures: utility of the second metacarpal-radius angle. J Child Orthop. 2009;3:375–381.
How to Cite this article: Doshi C. The magic of moulding – Applying upper limb cast in a child. Journal of Clinical Orthopaedics Jul-Dec 2022;7(2):15-17. |
(Abstract Full Text HTML) (Download PDF)